Ferric Chloride Thiourea and Brine Leaching to Extract Ag-Au

Independent mine operators have difficulty marketing complex gold-silver concentrates and ores. Generally, complex sulfide concentrates and ores cannot be handled by existing smelters. Even when handling them is technically possible, smelter charges and transportation costs become limiting factors. Hydrometallurgical methods are seriously being considered to provide a simple, inexpensive, low-pollution process to treat complex gold-silver ores on a small scale because building small smelters is generally not economically feasible.

Recovery of gold and silver has been based on caustic cyanidation since the 1890’s. However, not all ores are amenable to cyanidation, particularly those containing sulfides (chalcopyrite, sphalerite, galena, etc.). Gold and silver extraction is usually low and cyanide consumption is high because of base metal complex formation. Several researchers reported acidic thiourea to be more reactive and less affected by sulfide minerals in complex ores; but, as with caustic cyanide, gold and silver extraction is usually low with complex sulfide gold-silver ores. A procedure to extract silver from sulfide ores with FeCl3 was patented by Hey in 1922. Considerable work was completed by Wong to recover lead from a galena concentrate with a combined FeCl3-NaCl leach solution. Because both lead and silver were solubilized, silver recovery from high-silver ore would be difficult. Similar methods were used by Scheiner to extract silver and other metals from a complex sulfide concentrate. These methods required a Cl2-O2 or FeCl2-O2 leach at elevated pressure and temperature to form insoluble lead and silver chlorides, which were then solubilized in hot brine (PbCl2) and strong caustic cyanide solutions (AgCl).

The objective of this Bureau of Mines study was to investigate a hydrometallurgical method to recover silver, gold, and byproduct lead from a complex sulfide ore using an acid system at atmospheric pressure and moderate temperature. The proposed method consists of—

1. Leaching a sulfide ore with an acidic FeCl3 solution to form insoluble silver and lead chlorides. A portion of the zinc is also extracted:

Ag2S + 2 FeCl3 → 2 AgCl + 2 FeCl2 + S°…………………………………………….(A)

PbS + 2 FeCl3 → PbCl2 + 2 FeCl2 + S°………………………………………………(B)

ZnS + 2 FeCl3 → ZnCl2 + 2 FeCl2 + S°………………………………………………(C)

2. Solubilizing the silver and gold with an acidified thiourea leach solution and then recovering the gold and silver with ion-exchange resin, aluminum precipitation, or electrolysis:

AgCl + 3 CS(NH2)2 ↔ Ag(CS(NH2)2)3+ + Cl-……………………………………………(D)

Au + 2 CS(NH2)2 ↔ Au(CS(NH2)2)2+ + e-……………………………………………….(E)

3. Solubilizing the PbCl2 with an acidified NaCl brine leach solution:

leach-solution-equation

4. Recovering lead metal and regenerating the spent FeCl3 leach solution by electrolysis:

Pb²+ + 2e- = Pb (cathode)………………………………………………………………..(G)

2H+ + 2e- = H2 (cathode)……………………………………………………………….(H)

2Fe²+ = 2Fe³+ + 2e- (anode)……………………………………………………………(I)

2Cl- = Cl2 + 2e- (anode)………………………………………………………………….(K)

Materials

Material used in this study was obtained from a deposit in central Nevada. The chemical analysis of the ore is listed in

leach-solution-chemical-analysis-of-ore

The sample was dry-ground to minus 10 mesh in a laboratory roll crusher. Charges weighing 1 kg were wet-ground in distilled water at 50 pct solids using a 10-kg ball charge. Total grinding time was 45 min, which resulted in 90 pct of the material passing 200 mesh. The slurry was filtered, and the filter cake was dried at ambient temperature for several days.

Reagent-grade chemicals were used throughout the investigation. Analyses were conducted by atomic adsorption spectroscopy (AAS) or by fire assay. Gold analysis was somewhat erratic, and the results varied when test series were repeated; however, the trends were similar. This variation was probably because the gold was unevenly dispersed throughout the ore. FeCl2 concentration was determined by a standard dichromate titration and thiourea by an iodine titration.

Operating Procedure 

Leaching

Ferric Chloride

Because Wong extensively investigated extraction of lead from galena concentrates, only minimal effort was expended to investigate the FeCl3 leaching phase of the process. However, because Wong’s work was with a high-grade galena concentrate (74 pct Pb), some research was conducted to obtain maximum silver chloridization.

FeCL3 leach solution was prepared by adding reagent-grade FeCl3·6H2O to water acidified to pH 0.5 with HCl, and then heating to 40° C in a Pyrex beaker. Samples were mixed with the heated leach solution for a specified time, then filtered in a Buchner funnel containing fiberglass filter paper to separate the leach solution from the residue containing lead-silver chlorides and gold. The extent of AgCl and PbCl2 formation was determined by leaching the residue with 20 to 25 g/L NaCN at pH 11 to extract the AgCl, and with 250 g/L NaCl to extract the PbCl2. Without a pre-FeCl3 leach, silver extraction with the NaCN solution was about 20 pct. Results of the FeCl3 leach tests are listed in table 2. Silver extraction increased from 61 to 76 pct with increasing FeCl3 concentration, and from 76 to 95 pct as the retention time was increased from 3 to 6 h at the highest FeCl3 concentration. Zinc extraction increased with increasing FeCl3 concentration and was also somewhat dependent on time. Lead extraction was 93 pct with a 2-h leaching time, and increasing FeCl3 concentration did not increase lead extraction. Lead extraction was not followed further because of the research by Haver, who showed lead extraction from a galena concentrate to be 96 to 99 pct in 1 to 2 h at 50° C. Longer times and higher temperatures resulted in further dissolution of other elements, but did not significantly increase lead extraction.

leach-solution-ferric-chloride-leaching

Additional, larger scale tests were conducted to generate spent leach solution for electrolytic regeneration experiments and to generate residue for thiourea and brine leaching experiments to recover gold, silver, and lead. In these tests, 350 g FeCl3·6H2O was added to 3,500 mL of deionized water (acidified with 45 mL of concentrated HCl) and heated to 40° C in a 4-L beaker. Dried, minus 200-mesh material (175 g) was mixed with the leach solution for 6 h and filtered. Averaged analyses of the FeCl3 leach solutions and residues are listed in tables 3 and 4, respectively. The major metals present in the spent leach solution were iron, zinc, and lead. Zinc buildup in the recycled leach solution can possibly be controlled by pH adjustment and sulfide precipitation; however, Wong determined that zinc buildup reached a maximum of 15 g/L after many leaching cycles and did not cause a problem in that process. Further buildup of silver and lead in the leach solution is not anticipated because of their insolubility.

Thiourea

Laboratory tests were conducted to study the effect of thiourea concentration, H2SO4 concentration, CuSO4 addition, temperature, solids content, and retention time on leaching gold and silver. Residue from FeCl3 leaching, which had an analysis similar to that listed in

leach-solution analysis

leach-solution residue analysis

table 4, was used in the thiourea leaching investigation to extract gold and silver. Generally, the test procedure consisted of mixing 10 g of FeCl3 leach residue in 250 mL of leach solution containing 20 g/L thiourea and 4.6 g/L H2SO4, leaching for 3 h at 40° C, then filtering through Whatman No. 42 filter paper.

Increasing the initial thiourea concentration from 2 to 30 g/L increased silver extraction from 65 to 87 pct and gold extraction from 55 to 80 pct (fig. 1). Thiourea consumption increased from 5 to 67 lb/st.

H2SO4 had little effect on the silver, but increased H2SO4 concentration decreased gold extraction (fig. 2). Gold extraction increased from 70 to 80 pct as the H2SO4 concentration increased from 0 to 29.3 g/L but decreased to 50 pct at higher H2SO4 concentrations.

leach-solution-effect-of-thiourea-concentration

leach-solution-effect-of-h2so4

Previous research has shown that the presence of Cu²+ increases gold extraction by acting as an oxidation catalyst. Figure 3 shows that the addition of 6 g/L CuSO4-5H2O to the thiourea leach solution produced a maximum gold extraction of 85 pct. This was nearly 170 pct greater than the extraction obtained without CuSO4 addition. Silver extraction decreased slightly with the addition of this amount of CuSO4.

Increasing temperature increased gold extraction but had minimal effect on silver extraction (fig. A). Gold extraction increased from 25 to 50 pct as the temperature was increased from ambient to 40° C and to 65 pct at 73° C. Although thiourea consumption data were erratic, the trend clearly showed increased thiourea consumption with increased temperature—particularly above 40° C.

Figure 5 shows the effect of increasing solids content on gold and silver leaching using 20 g/L thiourea. Neither gold nor silver was affected to any great

leach-solution-gold-and-silver-extraction

leach-solution-effect-of-temperature

leach-solution effect of increased solids

extent as solids content was increased from 4 to 21 pct; however, above 21 pct solids, silver extraction decreased from between 75 to 80 pct down to 20 pct while gold extraction increased considerably.

All leach solutions, except those obtained from the tests with <7 pct solids, formed a white precipitate after filtration. The precipitate contained about 15 pct Pb, 1.2 oz/st Ag, and sulfur, which may indicate that a lead-silver thiourea complex had formed. Although solutions made with higher solids content are less table, a higher solids content has considerable advantage. As the solids were increased from 4 to 21 pct, silver in the leach solution increased from about 60 to 368 ppm. Thiourea consumption increased with increased solids, from about 36 lb/st residue, at 7 pct solids, to 46 lb/st residue at 21 pct solids.

The effect of retention time on precious metal extraction is shown in figure 6. Silver extraction was 70 pct complete in 15 min and increased to over 85 pct complete in 3 h. Gold extraction increased linearly from nearly 0 pct in 15 min to about 75 pct in 60 min, then decreased with additional time. Thiourea consumption also increased slightly with increased time.

Tables 5 and 6 list representative analyses of the thiourea leach solution and residue, respectively. The main contaminants in the leach solution were iron, lead, and zinc. The leach residue contained some silver and gold, along with PbCl2, and the remaining zinc and iron. A second thiourea leach did not extract significant gold or silver. Silver was reduced from 8 to 5 oz/st with a 20-g/L thiourea leach. Finer grinding may liberate more gold and silver.

leach-solution effect of time

leach-solution-thiourea-analysis

leach-solutionthiourea-residue-analysis

Thiourea consumption is a problem that was not resolved; however, a recent investigation by Schulze has shown that the addition of SO2 to the thiourea leach substantially reduces thiourea consumption.

Brine

Brine leach tests were conducted to study the effects of pulp density, acid concentration, and leach time on PbCl2 solubilization from the thiourea leach residue. Brine leach solution was prepared by adding 250 g/L NaCl to acidified water and heating to 55° C. Sufficient residue from the thiourea leach was added to the hot leach solution to vary the pulp density from 2 to 8.2 pct solids. The slurry was mixed for a specified time and filtered through a hot Buchner funnel. The solution was cooled to ambient temperature, and the PbCl2 crystals were filtered. Both the brine solution and PbCl2 crystals were saved for later use as feed to the cathode compartment of the electrolytic cell. The residue was saved for further treatment to recover the remaining silver and other valuable metals.

The effect of pulp density on PbCl2 solubilization from the thiourea leach residue is listed in table 7. At a 2-pct pulp density, the contained PbCl2 was completely solubilized. Increasing the pulp density to near 5.8 pct resulted in 95 pct of the PbCl2 being solubilized, and at a pulp density of 8.2 pct, only 81 pct was solubilized from the thiourea leach residue. The contained lead chloride is between 24 and 36 g/L at these pulp densities.

leach-solution-effect-of-residue-pulp

Additional tests were carried out to determine the effect of acid concentration on PbCl2 solubilization. All tests were conducted as described above, except the slurry contained 3.9 pct solids and the acid concentration was varied. Results listed in table 8 show that

leach-solution-effect-of-acid-strength

PbCl2 solubility increased slightly with increased acid strength, as did the impurity level of zinc, iron, and silver in the leach solution. Little advantage was gained by increasing acid concentration.

The time required to solubilize PbCl2 from the thiourea leach residue was less than 15 min. Tests conducted from 15 min to 2 h resulted in over 99-pct PbCl2 recovery. Iron and zinc impurities in the brine leach solution increased with time, as shown in table 9,

Tables 10 and 11 list analyses of representative brine leach solution (minus crystalized PbCl2) and residues, respectively. The only impurities in the pregnant brine solution of concern are silver, copper, and arsenic. Because of their position in the electromotive series, these metals will contaminate the lead metal produced during electrolytic recovery of byproduct lead. If necessary, these impurities can be

leach-solution-brine

leach-solution-brine-analysis

leach-solution-brine-residue-analysis

removed by passing the solution over lead shot. The brine leach residue contained small amounts of lead, which can be recovered with a second brine leach. Recovery of the remaining silver will be more difficult. A second thiourea leach was not effective in recovering silver, as discussed in the thiourea leach section. Additional work should be done to recover the remaining silver, zinc, and other metals.

Silver and Gold Recovery from Thiourea

Only minimal effort was expended to recover gold and silver from the thiourea leach solution. Previous work by Simpson showed that, gold and silver could be recovered from the thiourea leach solution with cation exchange resins, aluminum powder cementation, or electrolysis. The resin AG-50W-8X from Bio-Rad Laboratories successfully recovered the gold and silver with loadings on the resin of over 1,000 oz/st Ag and 100 oz/st Au. The resin was contacted with an acidified thiourea solution to strip the silver and with a caustic cyanide solution to strip the gold. Gold and silver were electrowon from their respective strip solutions on steel wool cathodes.

Aluminum powder (6 Al:1 Ag) added to thiourea leach solution containing 60 ppm Ag lowered the silver content to about 1 ppm. An acid leach will separate the silver from the aluminum-silver precipitate.

Byproduct Lead Recovery and Spent FeCl3 Leach Solution Recycle

Figure 7 shows the electrolytic cell used to recover lead from the brine solution and reoxidize the spent FeCl2-FeCl3 leach solution. The cell, similar to one discussed by Kramer, was constructed of Plexiglas and polypropylene, with the anode and cathode compartments separated, by an Ionics anion transfer membrane. Each compartment was 4.5 cm square with the anode compartment closed at the bottom. The cathode compartment was open at the bottom and had side holes for free flow of electrolyte between the cathode compartment and the 1,500-mL containment beaker. Cathode material was 6.35- by 3. 18-cm pure lead foil, and the anode was a platinum basket (1.27 cm diam by 5.08 cm).

In nearly all tests, the catholyte consisted of a 250-g/L NaCl brine solution containing 27 g/L PbCl2 and 0.6M HCl, and the anolyte was spent FeCl3 leach

leach-solution electrolytic cell

solution (table 3). Batch and semicontinuous experiments were conducted. All tests were initiated by adding 90 mL of spent FeCl3 leach solution (heated to 55° to 60° C) to the anode compartment, setting the cell into a 1,500-mL glass beaker, and adding 750 mL catholyte to the beaker. The platinum anode was put in the anode compartment, the power supply voltage was increased to slightly above 1 V, the lead cathode (precleaned with plastic scouring pad and washed with acetone) was placed into the cathode compartment, and the amperage was increased to give a current density of 100 A/m². The voltage was varied between 1.75 and 2.5 V. Usually, tests were conducted for 1.25 h. Cell agitation in the cathode compartment was supplied either by a magnetic stir bar or by nitrogen sparging. The only difference between semicontinuous and batch tests was that for semicontinuous tests anolyte was pumped from a beaker containing hot, spent FeCl3 leach solution into and out of the anode compartment at about 0.8 to 1.0 mL/min, and the catholyte was recirculated between a second beaker containing hot catholyte and the cell. Periodically, PbCl2 was added to the catholyte to maintain a relatively constant lead concentration during electrowinning. Following the test, the cathode was removed from the cell, washed with deionized water, and then dried with a lint-free tissue.

Operating parameters such as current density, leveling agent addition (bone gelatin and calcium lignin sulfonate), lead and acid concentration, agitation rate, and nitrogen sparging were investigated. The bone gelatin used in this investigation was the same as described by Cole. Cathode current efficiency remained above 95 pct with all tests; therefore, most of the effort was directed toward improving cathode surface.

Dendritic growth on the edges of the cathode was dramatically decreased by ensuring the cathode dimensions were larger than the anode dimensions, and by increasing solution agitation from minimal to moderate (enough to suspend any insoluble PbCl2 or additives).

The results of varying the current density (CD) from 50 to 248 A/m² with moderate catholyte agitation, no additive addition, and for 0.25 A·h are shown in table 12 and figure 8. Dendritic growth decreased as the CD decreased from 248 to 100 A/m². At lower CD, the cathode formed an oxidized coating.

leach-solution effect of current density

leach-solution lead cathode quality

Although reducing the CD decreased dendrite formation, the deposit was not acceptable. Others (18-20) have shown that organic compounds, referred to as leveling agents or additives, reduced dendrite formation and produced smooth lead deposits in a fluosilicic acid electrolyte and in chloride electrolytes. Animal glue, bone gelatin, and calcium lignin sulfonate were among the organics used. Preliminary tests with a PbCl2-NaCl electrolyte showed bone gelatin to have a slight advantage over animal glue. Calcium lignin sulfonate produced loosely adhering lead deposits when used with or without glue, but the dendrites were nodular rather than long and flat. Therefore, further testing was discontinued with calcium lignin sulfonate but continued with bone gelatin.

Bone gelatin addition to the catholyte eliminated dendrite formation and resulted in a smooth, shiny lead deposit as shown in figure 9 and table 13. All tests were conducted at 100 A/m² for 0.25 A·h. Bone gelatin concentration was varied from 0.1 to 2 g/L. Deposit quality increased with bone gelatin concentrations between 0.1 and 0.2 g/L, then decreased with increasing concentration. Effect on cell voltage was not significant.

leach-solution cathode quality

leach-solution effect of bone gelatin concentration

Results given in table 14 and figure 10 show the effects of PbCl2 concentration in the catholyte with 0.2 g/L bone gelatin at 100 A/m² for 0.25 A·h. At lower PbCl2 concentrations, the deposit was rough with short dendrites appearing over the entire cathode surface., As the PbCl2 concentration increased to 20 g/L, the dendrites disappeared, and finally, at 25 g/L PbCl2, a smooth, shiny, dendrite-free deposit was produced.

leach-solution-effect-of-pbcl2

Some additional testing was conducted to determine the effect of acid strength and nitrogen sparging. Nearly all tests were conducted with 0.6M HCl, but a test conducted with no acid addition resulted in an equally good cathode. These results indicate that acid may not be required for good cathode quality; however, this question has not been fully resolved. Kramer reported that nitrogen sparging under the cathode decreased dendrite growth considerably. Tests without glue addition and nitrogen sparging resulted in rough deposits with some dendrites on the edges. Glue addition with nitrogen sparging produced smoother deposits.

Semicontinuous tests were conducted to determine the cathode quality over several hours. All tests were conducted at 100 A/m² and with 0.2 g/L bone gelatin added to the PbCl2-NaCl catholyte. Lead chloride was added at 3-h intervals to keep the PbCl2 concentration between 22 and 25 g/L. The spent FeCl3 leach solution (18 g/L Fe²+ and 5 g/L Fe³+) was pumped through the anode compartment at 0.96 mL/min for 6 h and 45 min. Lead deposits were free of dendrites and shiny, but the surface was rough and nodular, as shown in figure 11.

leach-solution effect of pbcl2 concentration

leach-solution lead cathode

Process For Recovering Of Silver Gold, Lead, & Zinc in Complex Ores

A flow diagram for the integrated recovery of silver, gold, lead, and zinc shown in figure 12. In this process, a recycled FeCl3 leach solution was first readjusted to pH 0.5 with HCl and to about 23 g/L Fe³+ with FeCl3·6H2O; then 175- g of 90-pct minus 200-mesh ore, containing 50 oz/st Ag, 0.03 to 0.1 oz/st Au, 36 pct Pb, and 18 pct Zn, was added to this leach solution. The slurry was stirred and heated at 40° C for 6 h, then filtered. The spent leach solution was added to the lead electrolytic cell as an anolyte for solution regeneration. Zinc can be recovered, if necessary, by adjusting the pH to between 3.5 and 4, then precipitating with H2S. The FeCl3 leach residue containing the insoluble PbCl2 and AgCl plus any gold was leached at about 40° C for 3 h with about 1,400 mL of 20-g/L thiourea solution adjusted to pH 1.5 with H2SO4. After filtration, the gold and silver can be either precipitated with aluminum powder, electrowon, or adsorbed on Bio Rad AG-50W-8X cation exchange resin. The thiourea leach residue, which contained the PbCl2, was leached for 1 h at 55° to 60° C with about 3,000 mL of acidified 250-g/L NaCl brine solution to solubilize the PbCl2. The residue was either discarded or re-leached to recover other metal values.

leach-solution flow diagram

Lead was recovered from the hot PbCl2-NaCl brine solution in the anion perm-selective membrane electrowinning cell. Lead current efficiency was greater than 99 pet with a CD of 100 A/m² using 0.2 g/L bone gelatin addition. Ferrous oxidation at the anode was 75 to 99 pct at a cell temperature of 55° C.

Conclusions

Silver, gold, lead, and zinc were extracted from a complex lead-zinc sulfide ore sample with a sequential FeCl3, thiourea, and brine leach. FeCl3 extracted about 50 pct of the zinc and formed insoluble chlorides of silver and lead; thiourea extracted nearly 85 pct of the gold and silver, and an NaCl brine solution solubilized the PbCl2. Silver and gold were recovered from the thiourea leach solution by aluminum precipitation, cation-exchange resin, or direct electrowinning. Lead was recovered from the brine solution with a two-compartment anion permselective membrane electrolytic cell. Lead metal was recovered at the cathode, and spent FeCl3 was regenerated at the anode. Cathodic current efficiency was greater than 95 pct, and anodic current efficiency ranged from 75 to 99 pct.